For the complete documentation index, see llms.txt. This page is also available as Markdown.

Quality Observable with Inheres in (System, no Component)

This template is employed when the LOINC term involves an observation that is specified with a system, but not a component

This template is documented in Confluence here: Quality observable with Inheres in (System, no Component) for LOINC (observable entity) - v1.0

The java implementation of this template can be found here.

Attributes

  • LOINC Property: Represents the property of the observation, such as mass concentration or presence.

  • LOINC Scale: Describes the scale type, like quantitative or qualitative.

  • LOINC Time: Indicates the time aspect of the observation, e.g., single point in time.

  • LOINC System: Specifies the direct site of the observation.

  • LOINC Method: Describes the technique used for the observation.

LOINC Properties currently supported when LOINC Component is 'Observation': "Aper", "Color", "Rden", "Source","SpGrav","Temp"

Template

Model

=== 363787002 |Observable entity (observable entity)| : 
	{ 
		[S1] 370130000 |Property (attribute)| -> 718498007 |Appearance (property) (qualifier value)|,
		[S1] 370132008 |Scale type (attribute)| -> 117362005 |Nominal value (qualifier value)|,
		[S1] 370134009 |Time aspect (attribute)| -> 123029007 |Single point in time (qualifier value)|,
		[S1] 704319004 |Inheres in (attribute)| -> 258450006 |Cerebrospinal fluid specimen (specimen)| 
	}

Terming

Template slots are filled by taking the preferred term of the relevant value from the model and making the initial character lower case, if allowed by the case significance setting of the preferred term.

[PROPERTY] of [SYSTEM] at [TIME] by [METHOD] using [DEVICE] [CHALLENGE]

Some slots are optional, and are then tidied up along with any linking words (eg 'using')

The LOINC Long Common Name is specified as the Preferred Term and the LOINC Short Common Name is also included unchanged as an acceptable synonym. Finally a terse form of the LOINC Parts is added, with all part names specified, separated by colons.

In the case of the example below, this results in the following terms:

Concept Id
Description Id
Acceptability
Term
Case Significance

481481010000105

2211761010000110

US: P

Appearance of cerebrospinal fluid at point in time (observable entity)

ci

481481010000105

2211751010000113

US: P

Appearance of Cerebral spinal fluid

ci

481481010000105

2211771010000117

US: A

Appearance (CSF)

CS

481481010000105

2211781010000119

US: A

Observation:Aper:Pt:CSF:Nom

CS

481481010000105

2211741010000111

US: A

Appearance of cerebrospinal fluid at point in time

ci

Examples

LOINC Term 10333-3

Loinc Parts mapped to SNOMED Attributes

Part Type
LOINC Part Name
LOINC Part Num
Mapped to Attribute Type / Value

Property

Aper

LP6779-5

370130000 |Property (attribute)| -> 718498007 |Appearance (property) (qualifier value)|

Time

Pt

LP6960-1

370134009 |Time aspect (attribute)| -> 123029007 |Single point in time (qualifier value)|

System

CSF

LP7156-5

704319004 |Inheres in (attribute)| -> 258450006 |Cerebrospinal fluid specimen (specimen)|

Scale

Nom

LP7750-5

370132008 |Scale type (attribute)| -> 117362005 |Nominal value (qualifier value)|

Provide Feedback

Last updated