This template is employed when the LOINC term involves an observation that specifies an aspect of a process at a point in time where the process output is not included.
This template is documented here: Process Observable for LOINC - No Process output, With Time Aspect (observable entity) - v0.1
The java implementation of this template can be found here.
LOINC Property: Represents the property of the observation, such as mass concentration or presence.
LOINC Scale: Describes the scale type, like quantitative or qualitative.
LOINC Time: Indicates the time aspect of the observation, e.g., single point in time.
LOINC System: Specifies the direct site of the observation.
LOINC Method: Describes the technique used for the observation.
LOINC Component: Specifies what the observation inherently exists within or is associated with.
Template slots are filled by taking the preferred term of the relevant value from the model and making the initial character lower case, if allowed by the case significance setting of the preferred term.
Some slots are optional, and are then tidied up along with any linking words (eg 'using')
The LOINC Long Common Name is specified as the Preferred Term and the LOINC Short Common Name is also included unchanged as an acceptable synonym. Finally a terse form of the LOINC Parts is added, with all part names specified, separated by colons.
In the case of the example below, this results in the following terms:
LOINC Term
=== 363787002 |Observable entity (observable entity)| :
{ [S1] 246501002 |Technique (attribute)| -> 794261010000108 |Surface induced coagulation technique (qualifier value)|,
[S1] 370130000 |Property (attribute)| -> 762636008 |Duration (property) (qualifier value)|,
[S1] 370132008 |Scale type (attribute)| -> 30766002 |Quantitative value (qualifier value)|,
[S1] 370134009 |Time aspect (attribute)| -> 123029007 |Single point in time (qualifier value)|,
[S1] 424226004 |Using device (attribute)| -> 55091003 |Blood coagulation analyzer, device (physical object)|,
[S1] 704321009 |Characterizes (attribute)| -> 737094009 |Coagulation process (qualifier value)|,
[S1] 704327008 |Direct site (attribute)| -> 119297000 |Blood specimen (specimen)| }[PROPERTY] of [COMPONENT] at [TIME] in [SYSTEM] by [METHOD] using [DEVICE] [CHALLENGE]526891010000104
4734571010000118
US: P
Duration of coagulation process at point in time in blood by surface induced coagulation using blood coagulation analyzer (observable entity)
Property
Time
LP6879-3
370130000 |Property (attribute)| -> 762636008 |Duration (property) (qualifier value)|
ci
526891010000104
2611611010000115
US: P
aPTT in Blood by Coagulation assay
CS
526891010000104
4734561010000111
US: A
Duration of coagulation process at point in time in blood by surface induced coagulation using blood coagulation analyzer
ci
526891010000104
4734581010000115
US: A
aPTT Bld
CS
526891010000104
4734591010000117
US: A
Coagulation:Time:Pt:Bld:Qn:Coag.surface induced
CS
Time
Pt
LP6960-1
370134009 |Time aspect (attribute)| -> 123029007 |Single point in time (qualifier value)|
Component
Coagulation surface induced
LP15957-1
704321009 |Characterizes (attribute)| -> 737094009 |Coagulation process (qualifier value)|
System
Bld
LP7057-5
704327008 |Direct site (attribute)| -> 119297000 |Blood specimen (specimen)|
Scale
Qn
LP7753-9
370132008 |Scale type (attribute)| -> 30766002 |Quantitative (qualifier value)|
Method
Coag
LP6186-3
246501002 |Technique (attribute)| -> 702946003 |Coagulation technique (qualifier value)|
Method
Coag
LP6186-3
424226004 |Using device (attribute)| -> 55091003 |Blood coagulation analyzer, device (physical object)|