Constraints on Concept Requests

The SNOMED CT International Edition contains some concept hierarchies that have fundamental roles in supporting the design of SNOMED CT. Additions of concepts to these hierarchies may impact the consistency and integrity of SNOMED CT. The following pages set out guidance on the addition of extension concepts within specific hierarchies. In some cases, this guidance may prohibit extensions from adding concepts in a specific hierarchy or at a particular level of a hierarchy. In other cases, the advice is provided on the use case for making particular additions and notes are included on the implications and potential risks arising from such additions.

These constraints are expressed in tables in the following pages, which are arranged to follow the overall hierarchical structure of SNOMED CT.

  • Top Level Concepts and Clinical Concepts

  • Model Metadata Concept Hierarchies

Core Metadata Hierarchy
Foundation Metadata Concept Hierarchy
Linkage Concept Hierarchy
Namespaces
Provide Feedback

Top Level Concepts and Clinical Concepts

Top Level Concepts

Hierarchy

Purpose

The immediate subtype children of the root concept represent the most general types of SNOMED CT concepts.

Concept Addition Rules

It is strongly recommended that new top level concepts (i.e. direct subtype children of the root concept) are not added in an extension.

Additional Notes

Top Level Clinical Hierarchies

Namespaces

Namespace Concept

Hierarchy

Purpose

Each concept in this subhierarchy represents an allocated SNOMED CT extension namespace.

Examples

Concept Addition Rules

No new subtype children or descendants may be added in an extension.

Namespaces concepts can only be created by SNOMED International to represent allocated namespace identifiers.

Please see the section on Logical Design for a further introduction to namespaces.

Provide Feedback

Hierarchies

All direct subtype children of 138875005 | SNOMED CT Concept (SNOMED RT+CTV3)| except 900000000000441003 | SNOMED CT Model Component (metadata)| .

Purpose

These concepts represent a distinct type of clinical concept

Concept Addition Rules

Subtype descendants of the top level clinical concepts may be added in an extension.

Additional Notes

Concepts added in these hierarchies should conform with:

  • Concept model rules applicable to the relevant concept domain

  • Quality standards applicable to all SNOMED CT clinical content.

These concepts should be classified to generate a set of inferred relationships in necessary normal form, for inclusion in the extension distribution files.

Provide Feedback
138875005 | SNOMED CT Concept (SNOMED RT+CTV3)|

413335000 | Extension Namespace 1000003|

370136006 | Namespace concept|
373872000 | Core Namespace|
370137002 | Extension Namespace 1000000|
370138007 | Extension Namespace 1000001|
384597007 | Extension Namespace 1000002|

Model Metadata Concept Hierarchies

Core Metadata Concept

Hierarchy

Purpose

This concept is the supertype for all SNOMED CT metadata.

Concept Addition Rules

No new subtype children may be added in an extension.

Please refer to the following pages for guidance on the addition of subtype descendants.

All SNOMED CT metadata concepts are subtypes of 900000000000441003 | SNOMED CT Model Component (metadata)| and include concepts, descriptions and relationships that are used to describe or provide additional information about SNOMED CT content and reference sets.

The table below lists the subtypes of the 900000000000441003 | SNOMED CT Model Component (metadata)| hierarchy, and describes the content within these subhierarchies.

Table: Subhierarchies of |SNOMED CT Model Component| and their intended purpose

Subhierarchy
Purpose
Link to More Information

The following pages provide information about the subtypes of . Each page includes tables which describe the purpose of the content within one of the sub-hierarchies, with examples from the International Edition. The tables also state rules about the additions that are permitted in an extension to the respective subhierarchy. Where additions are permitted to the subhierarchy, notes are added on practical uses cases for addition, potential problems that may arise from these additions and any other relevant considerations.

OWL metadata concept (OWL metadata concept)

Contains concepts that are used in

  • OWL ontology reference set (OWL ontology header (OWL metadata concept) and OWL ontology namespace (OWL metadata concept))

  • OWL axiom reference set (Disjoint classes axiom (OWL metadata concept) and General concept inclusion axiom (OWL metadata concept))

Core metadata concept (core metadata concept)

Provides structural information required to support International Edition data. This supporting information includes sets of enumerated values that apply to attributes of concepts, descriptions and relationships.

Core Metadata Hierarchy

Foundation metadata concept (foundation metadata concept)

Provides supporting metadata and structural information for Reference Sets.

Foundation Metadata Concept Hierarchy

Linkage concept (linkage concept)

Links two or more concepts together to express compositional meanings. All concept codes that can be used as a Relationship Type are included under [

Linkage Concept Hierarchy

Namespace concept (namespace concept)

900000000000441003 | SNOMED CT Model Component (metadata)|
Core Metadata Hierarchy
Foundation Metadata Concept Hierarchy
Linkage Concept Hierarchy
Namespaces
Provide Feedback
900000000000441003 | SNOMED CT Model Component|

Contains concepts that represent an assigned Extension namespace identifier.

Linkage Concept Hierarchy

Linkage Concept

Hierarchy

Purpose

This concept is the supertype parent or ancestor of , , etc.

Concept Addition Rules

No new subtype children may be added in an extension

See tables below for concept addition rules for the descendants of existing subtype children.

Concept Model Attributes

Hierarchy

Purpose

These concepts provide the values for Relationship.typeId and represent the type of a defining relationship.

Examples

  • 260686004 | Method|

  • 260870009 | Priority|

  • 363704007 | Procedure site|

Concept Addition Rules

Additional attributes may be added in an extension, where required to support extensions to the SNOMED CT concept model.

Concept Addition Uses Cases

Extending the SNOMED CT concept model to allow sufficient definitions to be applied to concepts that are not sufficiently defined in the International Edition.

Additional Notes

Any attributes created in extensions need to be carefully managed and documented. Extension attributes may also need to be revised or inactivated to align with future changes to the concept model in the International Edition.

Hierarchy

416698001 | Link assertion|

Purpose

These concepts represent clinical assertions about relationships between instances of clinical statement in an EHR. For example, they may assert that a particular symptom is caused by something.

International Edition Examples

  • 417151001 | Has explanation|

  • 416271009 | Has problem member|

  • 416586004 | Has problem name|

  • 416083004 | Has reason|

Concept Addition Rules

Additional subtype children may be added in an extension. However, it is recommended that proposed additions be submitted to the International Edition, unless they are highly specific.

Concept Addition Uses Cases

Requirements to support additional types of assertion in clinical records

Link Assertions

Provide Feedback
106237007 | Linkage concept|
410662002 | Concept model attribute|
416698001 | Link assertion|
410662002 | Concept model attribute|
Namespaces

Core Metadata Hierarchy

Core Metadata Concept

Hierarchy

Purpose

This concept is the supertype for metadata used directly by SNOMED CT components.

Concept Addition Rules

No new subtype children may be added in an extension.

See tables below for concept addition rules for each of the subtypes of .

Characteristic Type

Hierarchy

Foundation Metadata Concept Hierarchy

417569004 | Has support|
416872009 | Is etiology for|
417318003 | Is manifestation of|

Purpose

The subtype children represent reference set types. Subtype descendents represent either reference sets of the type specified by their supertype parent or groups of reference sets of a type specified by their supertype parent.

Examples

Reference set types

Concept Addition Rules

New subtype children may be added in an extension, as long as they represent a new and distinct Reference Set Type (i.e. not an individual reference set).

New subtype descendants may be added in an extension, as long as they represent a Reference Set of the type defined by its supertype ancestors.

Concept Addition Uses Cases

  • To create a new reference set

  • To define a new reference set type

  • To define a group of related reference sets

Additional Notes

When a new reference set type is defined, an appropriate set of reference set descriptor rows must be created in the reference set descriptor reference set to specify the order and format of the reference set columns. Furthermore, the intended use and format of the new reference set type must also be documented.

Appropriate documentation should also be provided to describe the specific use of each individual reference set. The addition of reference set descriptor rows for individual reference sets is also recommended. However, this is optional if there are no additional constraints over and above those specified for its reference set type.

Hierarchy

Purpose

The subtype children represent named attributes used to represent columns in reference sets.

Also includes two special subtypes: and which are separately documented.

Examples

Concept Addition Rules

Subtype children can be added in an extension to represent new column names for use in additional reference set type definitions.

See separate notes on subtype descendance of the special subtypes and

Hierarchy

Purpose

These concepts represent data types associated with reference set attributes.

Examples

Concept Addition Rules

No new subtype children or subtype descendants may be added in an extension.

If new subtypes are required these should be requested for addition to the International Edition.

Hierarchy

Purpose

These concepts represent values that can be applied to specified columns in a reference set.

Concept Addition Rules

Additional subtype children may be added in an extension to represent values applicable to a newly added reference set or reference set type.

Subtype descendants should not be added in an extension, except where they are descendants of a subtype child added to support a newly added reference set.

Potential Problems

Adding subtype descendant to pre-existing subtype children would have the effect of changing the permitted value set for a pre-existing reference set type and reference sets defined as having that type.

Provide Feedback

Hierarchy

900000000000454005 | Foundation metadata concept|

Purpose

This concept is a supertype for metadata used to support SNOMED CT reference sets.

Concept Addition Rules

No new subtype children may be added in an extension.

See tables below for concept addition rules for each of the subtypes of 900000000000454005 | Foundation metadata concept|

Hierarchy

Foundation Metadata Concept

Reference Sets

Reference Set Attributes

Reference Set Attribute Types

Reference Set Attribute Values

Purpose

This subhierarchy provides the values for Relationship.characteristicTypeId.

Examples

  • 900000000000227009 | Additional relationship|

  • 900000000000006009 | Defining relationship|

  • 900000000000225001 | Qualifying relationship|

Concept Addition Rules

No new subtype descendants may be added in an extension.

Hierarchy

900000000000444006 | Definition status|

Purpose

This subhierarchy provides the values for Concept.definitionStatusId

Examples

  • 900000000000073002 | Defined|

  • 900000000000074008 | Primitive|

Concept Addition Rules

No new subtype descendants may be added in an extension.

Hierarchy

900000000000446008 | Description type|

Purpose

This subhierarchy provides the values for Description.typeId

Examples

  • 900000000000550004 | Definition|

  • 900000000000003001 | Fully specified name|

  • 900000000000013009 | Synonym|

Concept Addition Rules

Additional types permitted provided these are additive and do not replace the synonym or fully specified name values

Concept Addition Uses Cases

  • Different lengths of text for different purposes

  • Different formats for text including HTML

  • Specialized usage of text for a specific purpose

Hierarchy

900000000000450001 | Modifier|

Purpose

This subhierarchy provides the values for Relationship.modifierId

Examples

  • 900000000000452009 | All|

  • 900000000000451002 | Some|

Concept Addition Rules

No new subtype descendants may be added in an extension.

Hierarchy

900000000000443000 | Module|

Purpose

This subhierarchy provides the concepts used to identify modules

Examples

  • 900000000000207008 | SNOMED CT core|

  • 900000000000012004 | SNOMED CT model component|

  • 449081005 | SNOMED CT Spanish edition module|

  • 449080006 | SNOMED CT to ICD-10 rule-based mapping module|

Concept Addition Rules

The addition of modules that form part of the extension is required. These new module concepts must either be direct children of 900000000000443000 | Module| or descendants of a child of 900000000000443000 | Module| that is owned by the same extension provider. It is not permitted to add modules as subtypes of modules maintained by another extension provider.

Each module concept added within an extension must have an identifier that contains the extension's namespace identifier.

Concept Addition Uses Cases

The addition of at least one module concept is essential for all extensions. More than one module concept may be added to enable content to be organized into separate modules.

Definition Status

Description Type

Modifier

Module

Provide Feedback
900000000000442005 | Core metadata concept|
900000000000442005 | Core metadata concept|
900000000000449001 | Characteristic type|
449079008 | SNOMED CT to ICD-9CM equivalency mapping module|
900000000000522004 | Historical association| (This is a grouper concept not an actual reference set)
  • 900000000000526001 | REPLACED BY association reference set|

  • 900000000000527005 | SAME AS association reference set|

  • 900000000000480006 | Attribute value type|

  • 900000000000536009 | Source effective time|

    900000000000465000 | String (foundation metadata concept)|

    • 762678002 | OWL 2 language syntax (foundation metadata concept)|

    • 707000009 | SNOMED CT parsable string (foundation metadata concept)|

    • 900000000000466004 | Text (foundation metadata concept)|

    • 900000000000475002 | Time (foundation metadata concept)|

    900000000000455006 | Reference set|
    609331003 | Extended map type reference set|
    447562003 | ICD-10 complex map reference set|
    900000000000521006 | Association type|
    900000000000457003 | Reference set attribute|
    900000000000459000 | Attribute type|
    900000000000491004 | Attribute value|
    900000000000511003 | Acceptability|
    900000000000549004 | Acceptable|
    900000000000548007 | Preferred|
    900000000000501005 | Map group|
    900000000000459000 | Attribute type|
    900000000000491004 | Attribute value|
    900000000000459000 | Attribute type|
    900000000000459000 | Attribute type (foundation metadata concept)|
    900000000000460005 | Component type (foundation metadata concept)|
    900000000000461009 | Concept type component|
    900000000000476001 | Integer (foundation metadata concept)|
    900000000000491004 | Attribute value|
    900000000000469006 | Uniform resource locator (foundation metadata concept)|
    900000000000474003 | Universally Unique Identifier (foundation metadata concept)|

    Change Request Reporting Structure

    It is the responsibility of the extension producer to determine which requests are appropriate for their extension vs those which may be appropriate at a higher level. It is therefore important that extension producers are aware of the scope and the editorial principles for the International Edition of SNOMED CT and in some cases a national edition. This will ensure that requests for changes are forwarded to the relevant organization. Furthermore, it is important that extension producers have an established and reliable process for evaluating, processing, and overall tracking of all change requests received. The process needs to have a routing mechanism to ensure that changes applicable to the extension are made in the extension, and external change requests can be forwarded to the responsible organization, such as SNOMED International.

    The image below illustrates the reporting structure for SNOMED International content requests. In general, only NRCs report to SNOMED International directly. Other extension producers will report to SNOMED International indirectly. However, in some cases, an extension producers may submit change requests directly to SNOMED International. For example, if the extension producer is an Affiliate, based in a non-Member territory.

    Change request reporting structure

    National Release Centers are responsible for collecting requests for changes detected by Affiliates. Typically requests come from the users or consumers of the extension as they are most familiar with local requirements. Organizations within Member countries can, therefore, submit their requests for additions and changes to the National Release Center who will make an initial decision about the relevance of the content in the International Edition or the national edition of that country. The NRC may add content to their National Edition if they consider the relevance to be national rather than international. The NRC forwards requests with (what they consider to have) international relevance to SNOMED International for consideration.

    For more information about the processes in each country, please consult the relevant page.

    SNOMED International provides the to gather and process requests for additions and changes to the content of the SNOMED CT International Edition. This service is directly accessible by National Release Centers (NRC) in Member countries and recognized Terminology Authorities within organizations with whom SNOMED International is actively collaborating. Requests that meet inclusion criteria for the International Release are addressed by SNOMED International staff. Some of the reasons behind International content requests are described in the table below.

    Table: Reasons for requesting content to be added to the International Edition

    Example use case
    Description

    If a request is deemed to have high priority, it should result in action in the next release cycle. However, requests constituting a significant change which impacts other content may take longer to implement. If a request is declined, a reason and explanation are provided to the requester, who may choose to appeal the decision to the Head of Terminology. For more information about the CRS, please refer to the .

    Assessing Requests

    Once requirements have been identified and submitted as requests for additions or changes, the extension producer need to review and assess these requests. This entails an assessment of whether the requested content is relevant for inclusion in:

    • The International Edition

    • A National extension

    • Another extension

    Gaps in coverage of scope

    Clinical meanings that fall within the scope of the International Edition that are not currently represented by concepts in the International Edition

    Changes in clinical knowledge

    Evolving clinical knowledge introduces clinical meanings that require the addition of new SNOMED CT concepts

    Incomplete definitions

    A concept in the International Edition that is missing one or more valid defining relationships

    Missing synonyms

    A concept in the International Edition that is missing one or more widely used synonymous terms

    Member
    SNOMED CT Content Request Service
    CRS User Guide
    Provide Feedback
    This extension (i.e. the one being managed by this extension producer)

    Requests will typically be for addition of new components (concepts, descriptions or relationships) or changes to or inactivation of existing SNOMED CT components or reference sets. However, sometimes there are requests for a completely new reference set.

    As part of the assessment process to determine where the requested content belongs, these points should be taken into consideration:

    1. The scope of various SNOMED CT Editions

    2. Whether the request is permitted given the predefined principles around:

      1. Editorial rules and;

      2. Retaining the referential integrity of SNOMED CT

    When a SNOMED CT Member, or Affiliate organization which maintains an extension, identifies a requirement for new content they should evaluate the request by considering the following questions:

    • Does the requested content fall within the defined scope of the International Edition?

    • Is the requested content likely to be required by, or of value to, more than one Member territory?

    If the answer to both these questions is "yes", then organization should submit a request to SNOMED International for inclusion of the new content. When a request originates in an Affiliate organization, it should be submitted to a National Release Center who will then forward the request to SNOMED International. In general, this content should not be added to a National or local extension, as content that falls within the defined scope of the International Edition and is required by two or more Member territories. However, in cases where there is an urgent requirement, an extension producer may add the content to their own extension as an interim solution. Please refer to Interim Content Additions below.

    Similarly, if the answer to one or both of these questions is "no", the content may be suitable for inclusion in a National Edition. In this case, the following questions should be considered:

    • Does the requested content fall within the defined scope of a National Edition?

    • Is the requested content likely to be required by, or of value to, more than one organization within the Member territory?

    If the answer to both these questions is "yes", then organization should submit a request to the National Release Center for addition of the required content into the National Edition. If the answer to one or both of these questions is "no", it should be considered for inclusion in a local extension. In situation where the request is considered to be out of scope of SNOMED CT, it may be rejected. The table below provides additional detail on the various outcomes in these considerations.

    Table: Considerations relating to appropriateness of content at various levels

    When determining whether or not a request for additions or changes should be accepted for inclusion in any SNOMED CT edition, it is important to ensure that the addition or modification does not break the referential integrity of SNOMED CT. It is also important to assess whether the definition on new concepts has undesirable effects on the existing content. Finally, it should be ensured that every addition of or modification to SNOMED CT concepts conform to the rules specified by the concept model. The describes key principles which ensure that referential integrity is retained and that components and reference sets are created or modified in an extension in accordance with the editorial principles.

    SNOMED International does not recommend that extension producers make changes which result in modifications to the International release as this can cause interoperability issues. Substantive errors, or improvements to content in the International release which are mitigated by content in an extension, should therefore be forwarded to SNOMED International in a timely fashion to improve the quality of the International release.

    In circumstances where the International release has been impacted by modifications in a national or local extension, a disclaimer notifying users of the differences between the extension release and the International release must accompany the national extension distribution files.

    Before content is added to a national or International Edition, organizations may choose to add this content to a module they own as an interim measure. In these cases, the organization should indicate, as part of the request, that an interim addition has been made, but that the content should ultimately be promoted to the International Edition. When a request for content which is relevant at the national level is submitted to a NRC that maintains a National Edition, interim content from a local extension may be promoted to that National Edition.

    For example:

    • Local organizations in a country or region may add components to their local extension and then forward the request to their NRC

    • An NRC may add components in their national extension and then forward a request to SNOMED International for inclusion in the International Edition

    Note that, content added to an extension can later be promoted to another extension or to the International Edition. For more information, please refer to .

    It is the responsibility of the extension producer to determine which requests are appropriate for their extension vs those which may be appropriate at a higher level. It is therefore important that extension producers are aware of the scope and the editorial principles for the International Edition of SNOMED CT and in some cases a national edition. This will ensure that requests for changes are forwarded to the relevant organization. Furthermore, it is important that extension producers to have an established and reliable process for evaluating, processing, and overall tracking of all change requests received. The process needs to have a routing mechanism to ensure that changes applicable to the extension are made in the extension, and external change requests can be forwarded to the responsible organization, such as SNOMED International.

    The image below illustrates the reporting structure for SNOMED International content requests. In general, only NRCs report to SNOMED International directly. Other extension producers will report to SNOMED International indirectly. However in somes cases, an extension producers may submit change requests directly to SNOMED International. For example, if the extension producer is an Affiliate, based in a non-Member territory.

    National Release Centers are responsible for collecting requests for changes detected by Affiliates. Typically requests come from the users or consumers of the extension as they are most familiar with local requirements. Organizations within Member countries can therefore submit their requests for additions and changes to the National Release Center who will make an initial decision about the relevance of the content in the International Edition or the national edition of that country. The NRC may add content to their National Edition if they consider the relevance to be national rather than international. The NRC forwards requests with (what they consider to have) international relevance to SNOMED International for consideration.

    For more information about the processes in each country, please consult the relevant page.

    SNOMED International provides the to gather and process requests for additions and changes to the content of the SNOMED CT International Edition. This service is directly accessible by National Release Centers (NRC) in Member countries and recognized Terminology Authorities within organizations with whom SNOMED International is actively collaborating. Requests that meet inclusion criteria for the International Release are addressed by SNOMED International staff. Some of the reasons behind International content requests are described below.

    Table: Reasons for requesting content to be added to the International Edition

    Example use case
    Description

    If a request is deemed to have high priority, it should result in action in the next release cycle. However, requests constituting a significant change which impacts other content may take longer to implement. If a request is declined, a reason and explanation are provided to the requester, who may choose to appeal the decision to the Head of Terminology. For more information about the CRS, please refer to the .

    Assessing Requests

    Relevance of requested content

    Description

    Within the scope of the International Edition

    If the content requested is within the scope of the International Edition, the organization should request that the content should be added to the International Edition.

    As SNOMED CT is a global clinical terminology, the scope of the International edition of SNOMED CT is constrained by a set of principles. For inclusion in the International edition, concepts must be

    • Useful in more than one country

    • Necessary for healthcare conformance and interoperability

    • Within the scope of a clinical terminology

    • Satisfy the criteria of being understandable, reproducible, useful

    If there is an urgent need for additional content, it may be added to an extension as an interim measure, pending addition to the International Edition. For more information, please refer to Interim content additions below.

    Within the scope of other extension, (National, third-party, or local extension) but outside the scope of the International Edition.

    The scope of a national edition may permit the addition of content which falls outside the scope of the International Edition but is required within a country, region or territory. If the content requested is within the scope of a national edition, a request should be submitted to the relevant National Release Center.

    An organization may also use an extension which was produced by another organization, such as a vendor, regional body or specialist group. In this case, requests for content which fall within the scope of these extensions should be submitted to the relevant extension producer.

    When there is an urgent need for additional content, it may be added to an extension as an interim measure, pending addition to a national edition or externally maintained extension. For more information, please refer to Interim content additions below.

    Outside the scope of other extensions, but relevant to the organization requesting the content.

    An organization which maintains an extension is responsible for defining the scope of that extension. The scope of an extension should not overlap with the scope of the International Edition or any other extension with modules on which the extension modules depend on. Note that urgent content additions may be permitted as an interim measure, even when the content is within the scope of another edition or extension. For more information. please refer to Interim content additions below.

    Requested content which falls within the defined scope of an extension may be added by the organization which maintains the extension. For additional information about adding local content to an extension, please refer to Authoring.

    Outside the scope of SNOMED CT

    The request is rejected

    Gaps in coverage of scope

    Clinical meanings that fall within the scope of the International Edition that are not currently represented by concepts in the International Edition

    Changes in clinical knowledge

    Evolving clinical knowledge introduces clinical meanings that require the addition of new SNOMED CT concepts

    Incomplete definitions

    A concept in the International Edition that is missing one or more valid defining relationships

    Missing synonyms

    A concept in the International Edition that is missing one or more widely used synonymous terms

    Important Considerations

    Scope

    Referential Integrity and Editorial Principles

    Final disclaimer goes here: (proposal found here: Re: SNOMED International response to "Discussion paper - Allowance of Extensions to Modify Core Content" ver. 2.0)

    Interim Content Additions

    Change Request Reporting Structure

    Authoring section
    Promotion and Demotion
    Member
    SNOMED CT Content Request Service
    CRS User Guide
    Provide Feedback
    Change request reporting structure
    Content for the OWL Ontology Refset
    Content for the OWL Axiom Refset

    Interim Content Additions

    Before content is added to a national or International Edition, organizations may choose to add this content to a module they own as an interim measure. In these cases, the organization should indicate, as part of the request, that an interim addition has been made, but that the content should ultimately be promoted to the International Edition. When a request for content which is relevant at the national level is submitted to a NRC that maintains a National Edition, interim content from a local extension may be promoted to that National Edition.

    For example:

    • Local organizations in a country or region may add components to their local extension and then forward the request to their NRC

    • An NRC may add components in their national extension and then forward a request to SNOMED International for inclusion in the International Edition

    Note that, content added to an extension can later be promoted to another extension or to the International Edition. For more information, please refer to 5.4.1.1 Promotion and Demotion.

    Considerations In Assessing Requests

    As part of the assessment process to determine where the requested content belongs, following points are important to take into consideration:

    1. The scope of various SNOMED CT Editions

    2. Whether the request is permitted given the predefined principles around:

      1. Editorial rules and;

    Provide Feedback
    Retaining the referential integrity of SNOMED CT

    When a SNOMED CT Member, or Affiliate organization which maintains an extension, identifies a requirement for new content they should evaluate the request by considering the following questions:

    • Does the requested content fall within the defined scope of the International Edition?

    • Is the requested content likely to be required by, or of value to, more than one Member territory?

    If the answer to both these questions is "yes", the organization should submit a request to SNOMED International for the inclusion of the new content. When a request originates in an Affiliate organization, it should be submitted to a National Release Center who will then forward the request to SNOMED International. In general, this content should not be added to a National or local extension, as content that falls within the defined scope of the International Edition and is required by two or more Member territories. However, in cases where there is an urgent requirement, an extension producer may add the content to their own extension as an interim solution. Please refer to Interim Content Additions below.

    Similarly, if the answer to one or both of these questions is "no", the content may be suitable for inclusion in a National Edition. In this case, the following questions should be considered:

    • Does the requested content fall within the defined scope of a National Edition?

    • Is the requested content likely to be required by, or of value to, more than one organization within the Member territory?

    If the answer to both these questions is "yes", then the organization should submit a request to the National Release Center for the addition of the required content into the National Edition. If the answer to one or both of these questions is "no", it should be considered for inclusion in a local extension. In a situation where the request is considered to be out of the scope of SNOMED CT, it may be rejected. The table below provides additional detail on the various outcomes in these considerations.

    Table: Considerations relating to appropriateness of content at various levels

    When determining whether or not a request for additions or changes should be accepted for inclusion in any SNOMED CT edition, it is important to ensure that the addition or modification does not break the referential integrity of SNOMED CT. It is also important to assess whether the definition of new concepts has undesirable effects on the existing content. Finally, it should be ensured that every addition of or modification to SNOMED CT concepts conform to the rules specified by the concept model. Section describes key principles which ensure that referential integrity is retained and that components and derivatives are created or modified in an extension in accordance with the editorial principles.

    SNOMED International does not recommend that extension producers make changes which result in modifications to the International release as this can cause interoperability issues. Substantive errors, or improvements to content in the International release which are mitigated by the content in an extension, should, therefore, be forwarded to SNOMED International in a timely fashion to improve the quality of the International release.

    In circumstances where the International release has been impacted by modifications in a national or local extension, a disclaimer notifying users of the differences between the extension release and the International release must accompany the national extension distribution files.

    Considerations in Assessing Requests

    Relevance of requested content

    Description

    Within the scope of the International Edition

    If the content requested is within the scope of the International Edition, the organization should request that the content should be added to the International Edition.

    As SNOMED CT is a global clinical terminology, the scope of the International edition of SNOMED CT is constrained by a set of principles. For inclusion in the International edition, concepts must be

    • Useful in more than one country

    • Necessary for healthcare conformance and interoperability

    • Within the scope of a clinical terminology

    • Satisfy the criteria of being understandable, reproducible, useful

    If there is an urgent need for additional content, it may be added to an extension as an interim measure, pending addition to the International Edition. For more information, please refer to Interim content additions below.

    Within the scope of another extension, (National, third-party, or local extension) but outside the scope of the International Edition.

    The scope of a national edition may permit the addition of content which falls outside the scope of the International Edition but is required within a country, region or territory. If the content requested is within the scope of a national edition, a request should be submitted to the relevant National Release Center.

    An organization may also use an extension which was produced by another organization, such as a vendor, regional body or specialist group. In this case, requests for content which fall within the scope of these extensions should be submitted to the relevant extension producer.

    When there is an urgent need for additional content, it may be added to an extension as an interim measure, pending addition to a national edition or externally maintained extension. For more information, please refer to Interim content additions below.

    Outside the scope of other extensions, but relevant to the organization requesting the content.

    An organization which maintains an extension is responsible for defining the scope of that extension. The scope of an extension should not overlap with the scope of the International Edition or any other extension with modules on which the extension modules depend on. Note that urgent content additions may be permitted as an interim measure, even when the content is within the scope of another edition or extension. For more information. please refer to Interim content additions below.

    Requested content which falls within the defined scope of an extension may be added by the organization which maintains the extension. For additional information about adding local content to an extension, please refer to Authoring.

    Outside the scope of SNOMED CT

    The request is rejected

    Scope

    Referential Integrity and Editorial Principles

    Authoring
    Provide Feedback