Reference sets can be added in an extension to meet specific national or local requirements. Reasons for adding a reference set include:
Specifying a subset of components for inclusion or exclusion
Mapping between SNOMED CT and other code systems to support data integration or communication
Specifying the acceptability of descriptions in a given language or dialect
For more information about a range of purposes for reference sets, please refer to the Practical Guide to Reference Sets.
When creating a new reference set it is important that the reference set metadata concept (which identifies and names the reference set) and the associated reference set members belongs to a module of the reference set producer. I.e. if a reference set is created as part of an extension, the reference set metadata concept should belong to a module within the namespace of the extension producer.
All reference sets follow a logical model. Each reference set type is represented by a specific data structure which enables a specific functionality. SNOMED International specifies a set of reference set types, which can be used to support a set of terminology management purposes. SNOMED CT Members (National Release Centers) and Affiliates may also create reference sets to assist with localization and effective implementation of SNOMED CT. In general, an extension producer can create a reference set within their extension, but the reference set type should be defined in either
The producers extension
The International Edition
Other extensions (which the producers extension modules are dependent on)
For more information about the different reference set types and their data structures, please refer to the .
Please note that for all reference sets, there should be guidance on what is possible and what is not possible. For some International reference sets, it is acceptable and even required to add extension rows to the International reference set. For example, the Module Dependency Refset, the MRCM Module Scope Refset, and Language Refset. This is not necessarily applicable to all reference sets. Over time, further guidance in this area will be developed.
The table below provides a summary of the process to follow when creating a new reference set.
Define the reference set in the metadata hierarchy Following steps should be taken for creating the reference set concept:
Define the reference set Attributes within the metadata hierarchy
Add new concepts for each of the reference set member attributes, if necessary. If the reference set attributes describing the pattern are adequate to describe the reference set's attributes, then these can be used instead. You may add new concepts for some of the attributes, and reuse existing concepts for other attributes, if you wish.
Create the Descriptor for the reference set
If the reference set does not follow an existing reference set pattern, the additional attributes specific for this customized reference set should be included in the .
Add members to the reference set
Reference set members are added to the reference set, which includes specifying the attribute values for each reference set member, see .
For additional information, see the practical guide to reference sets: How to create a new Reference Set using an existing pattern
Concept file
Create a concept for the reference set
Description file
2. Add up to three Descriptions for the reference set concept. I.e. the FSN, the Preferred Term and optionally the purpose, see
Language reference set
Specify the acceptability of the descriptions in the applied Language Reference Set
Relationship file
4. Add an | is a | Relationship to link the reference set to the appropriate pattern
Concept
1. Add a concept for the attribute
Description
2. Add Descriptions for each of the new attribute.
Language Reference Set
Specify the acceptability of the descriptions in the applied Language Reference Set
Relationship
4. Link the attribute with an | is a | Relationship into the hierarchy
Reference Set Descriptor Reference Set
A new reference set member is created in the reference set Descriptor for each attribute in the reference set pattern. For guidance on creating a reference set member, please see . For further introduction to the reference set Descriptor, please see in .
There are three distinct situations in which an extension producer may end support for a reference set in an extension.
Responsibility for maintenance of a reference set is transferred to another extension producer or to SNOMED International
For example, a reference set currently maintained as part of a National extension may be transferred to SNOMED International if it has recognized international value.
A decision is made to stop maintaining a reference set, without transferring the responsibility to another organization
For example, an organization may no longer have the resources to maintain a reference set that it created, although the reference set is still considered useful.
A decision is made to deprecate use of an existing reference set
For example, if a reference set is no longer relevant, has been superseded by a more useful reference set, or is considered inaccurate or misleading in some way.
When the owner of a reference set wants to end support for the reference set, this should be indicated by making the changes described in the process section below.
In the situation where the reference set belongs to an extension, the owner of the extension may only make these changes to a reference set that is currently in an extension module for which it is responsible. The exception to that rule is that, in the case where a responsibility for maintenance of a reference set is transferred to another organization, the organization to which responsibility is transferred is required to take some of these steps.
Prior to ending support for a reference set, it is important that the reference set producer has an overview of the extent to which the reference set is used. If a producer and owner of a reference set continues to distribute an unsupported reference set with active members, there is an inherent risk that it will continue to be used. However, deprecation formally inactivates the reference set members to minimise this possibility.
The table below provides details and considerations on the process of inactivating a reference set.
If the extension producer wants to avoid users from needing to import a deprecated or transferred reference set in future releases, the inactivated reference set may be separated from the main extension release (e.g. it could be in a separate release package, or accessible via a separate service or from a static location). Changes in packaging must be formally notified to users of the extension in advance of the change.
Deprecating continued use of a reference set
Inactivate the reference set concept and metadata following the process described in .
Inactivate all the members of the reference set following the process described in .
Add a row to the indicating the reason for inactivation of the reference set.
Ensure that documentation explaining this change is prepared and distributed to all users of the extension.
Transfer of responsibility for maintenance to an organization that is responsible for a module on which the current module depends
Request the newly responsible organization to issue new versions of the reference set concept, metadata and active reference set members using the same identifiers but changing the moduleId to refer to the module in which the reference set is now being maintained.
Inform users that the reference set is now being maintained by another organization.
Do not inactivate or otherwise alter any of the existing concepts or reference set members.
Ensure that documentation explaining this change is prepared and distributed to all users of the extension.
Create new versions of the reference set concept and related metadata. The new versions of components must have the updated effectiveTime for the relevant release date and the moduleId of the module in which the reference set will now be maintained. However, the id and all other fields must have the same values as in the original versions.
Create new versions of all active members from of the reference set. The new versions of references set members must an updated effectiveTime for the relevant release date and the moduleId of the module in which the reference set will now be maintained. However, the id, refsetId and all other fields must have the same values as in the original versions.
Transfer of responsibility for maintenance to an organization that is not responsible a module on which the current module depends
Request the newly responsible organization to create and maintain a new reference set in their own extension module. The newly created reference set concept and metadata should replicate the and includes all all the members of the original reference set that were active immediately prior to deprecation.
Inactivate the original reference set concept and metadata following the process described in Inactivate Concept in an Extension.
Inactivate all the members of the original reference set following the process described in Remove Members from a Reference Set.
Add a row to the indicating the reason for inactivation of the reference set.
Ensure that documentation explaining this change is prepared and distributed to all users of the extension.
Create a new reference set following the process described in Create a New Reference Set. The reference set must have a newly allocated id, the updated effectiveTime for the relevant release date and the moduleId of the module in which the reference set is being created. However, the name and all other fields should have the same values as in the original versions.
Create new members of the newly created reference set following the process described in Add Members to a Reference Set. A member must created matching each of the active members of original reference set.
Create a row in the | REPLACED BY association reference set| indicating that the original reference set has been replaced by this reference set.
Ending maintenance of without formally deprecating continued use of a reference set
Inactivate the reference set concept, following the process described in Inactivate Concept in an Extension.
Do not inactivate the members of the reference set.
Add a row to the | Concept inactivation indicator reference set| indicating the reason for inactivation of the reference set.
Ensure that documentation explaining this change is prepared and distributed to all users of the extension.
Depending on the type of reference set, there may be different reasons for modifying the reference set, including:
Promoting the reference set to a parent module, for example the International Edition
Transfer of responsibility for maintenance to an organization that is responsible for a module on which the current module depends, see
Principles for modifying reference sets include:
Reference sets can be modified by changing the value of the active attribute or the value of the moduleId attribute, i.e. for activating or inactivating the reference set, or moving the reference set to another module (a module on which the current module depends).
The reference set metadata concept is always primitive and the concept can therefore not be changed from primitive to fully defined, or from fully defined to primitive, i.e. the value of the definitionStatusId attribute should be primitive for all versions of the reference set
The reference set type should not be changed, i.e. the |is a| relationship, linking the reference set to the appropriate reference set type concept should not be changed
The only situation where the the reference set type may change is if the reference set was originally misplaced in the SNOMED CT hierarchy.
If the reference set needs to be changed to a different type, (for example, from a simple reference set to an ordered component type reference set) then it would require the original reference set to be inactivated and a new reference set to be created in accordance with the Descriptor for that reference set type.
Reference sets that belong to a module which is not managed by the extension producer should not be modified.
Modifying a reference set created within the extension module
The process for modifying the reference set concept, is similar to the general process for modifying concepts in SNOMED CT. Therefore, please refer to for further guidance.
Authoring reference sets in an extension may involve adding, modifying or inactivating members of a reference set, or the reference set itself.
The sections that follow will examine the purpose, principles and process for each of these authoring tasks.