Quality Observable with Component
This template is utilized when the LOINC term represents a quality observable with a component. It's suitable for measurements or observations that involve a specific component.
Attributes
LOINC Property: Represents the property of the observation, such as mass concentration or presence.
LOINC Scale: Describes the scale type, like quantitative or qualitative.
LOINC Time: Indicates the time aspect of the observation, e.g., single point in time.
LOINC System: Specifies the direct site of the observation.
LOINC Method: Describes the technique used for the observation.
LOINC Component: Represents the specific component being measured or observed.
LOINC Properties currently supported: "ACnc", "CCnc", "CCnt", "LaCnc", "LnCnc", "LsCnc", "MCnc", "MCnt", "MoM", "NCnc", "Naric", "PPres", "PrThr", "SCnc", "SCnt", "Titr"
Template
Model
=== 363787002 |Observable entity (observable entity)| :
{
246093002 |Component (attribute)| -> 120771002 |Antibody to Trypanosoma cruzi (substance)|,
246501002 |Technique (attribute)| -> 726449005 |Immunoassay technique (qualifier value)|,
370130000 |Property (attribute)| -> 118569000 |Arbitrary concentration (property) (qualifier value)|,
370132008 |Scale type (attribute)| -> 30766002 |Quantitative (qualifier value)|,
370134009 |Time aspect (attribute)| -> 123029007 |Single point in time (qualifier value)|,
704327008 |Direct site (attribute)| -> 119364003 |Serum specimen (specimen)|
}
Terming
Template slots are filled by taking the preferred term of the relevant value from the model and making the initial character lower case, if allowed by the case significance setting of the preferred term.
[PROPERTY] of [COMPONENT] in [SYSTEM] at [TIME] by [METHOD] using [DEVICE] [CHALLENGE]481191010000118
Some slots are optional, and are then tidied up along with any linking words (eg 'using')
The LOINC Long Common Name is specified as the Preferred Term and the LOINC Short Common Name is also included unchanged as an acceptable synonym. Finally a terse form of the LOINC Parts is added, with all part names specified, separated by colons.
In the case of the example below, this results in the following terms:
481171010000119 [138811010000103] US: P Arbitrary concentration of Trypanosoma cruzi antibody in serum at point in time by immunoassay (observable entity) [cI],
481191010000118 [138811010000103] US: P Trypanosoma cruzi Ab [Units/volume] in Serum by Immunoassay [CS],
481201010000115 [138811010000103] US: A Trypanosoma cruzi Ab:ACnc:Pt:Ser:Qn:IA [CS],
2196621010000117 [138811010000103] US: A T. cruzi Ab IA Qn (S) [CS]
481191010000118 [138811010000103] US: A Arbitrary concentration of Trypanosoma cruzi antibody in serum at point in time by immunoassay [cI]
Examples
LOINC Term 100091-8
Loinc Parts
Component
Trypanosoma cruzi Ab
LP40073-6
246093002 |Component (attribute)| -> 120771002 |Antibody to Trypanosoma cruzi (substance)|
Property
ACnc
LP6773-8
370130000 |Property (attribute)| -> 118569000 |Arbitrary concentration (property) (qualifier value)|
Time
Pt
LP6960-1
370134009 |Time aspect (attribute)| -> 123029007 |Single point in time (qualifier value)|
System
Ser
LP7567-3
704327008 |Direct site (attribute)| -> 119364003 |Serum specimen (specimen)|
Scale
Qn
LP7753-9
370132008 |Scale type (attribute)| -> 30766002 |Quantitative (qualifier value)|
Method
IA
LP217197-5
246501002 |Technique (attribute)| -> 726449005 |Immunoassay technique (qualifier value)|
Last updated