Quality Observable with Inheres In

This template is employed when the LOINC term involves an observation that inherently exists within or is associated with something else.

This template is documented in Confluence here: Quality observable with Inheres in for LOINC (observable entity) - v1.0

The java implementation of this template can be found: https://github.com/IHTSDO/reporting-engine/blob/develop/script-engine/src/main/java/org/ihtsdo/termserver/scripting/pipeline/loinc/LoincTemplatedConceptWithInheres.java

Attributes

  • LOINC Property: Represents the property of the observation, such as mass concentration or presence.

  • LOINC Scale: Describes the scale type, like quantitative or qualitative.

  • LOINC Time: Indicates the time aspect of the observation, e.g., single point in time.

  • LOINC System: Specifies the direct site of the observation.

  • LOINC Method: Describes the technique used for the observation.

  • LOINC Component: Specifies what the observation inherently exists within or is associated with.

LOINC Properties currently supported when LOINC Component is not 'Observation:' "Anat", "DistWidth", "EntMCnc", "EntMeanVol", "ID", "Morph", "Prid", "Type", "Vol"

Template

Model

=== 363787002 |Observable entity (observable entity)| : 
	{
		370130000 |Property (attribute)| -> 410656007 |Type (property) (qualifier value)|, 
 		370132008 |Scale type (attribute)| -> 117362005 |Nominal value (qualifier value)|, 
 		370134009 |Time aspect (attribute)| -> 123029007 |Single point in time (qualifier value)|, 
 		704319004 |Inheres in (attribute)| -> 16951006 |Antigen in Rh blood group system (substance)|, 
 		704327008 |Direct site (attribute)| -> 119297000 |Blood specimen (specimen)| 
	}

Terming

Template slots are filled by taking the preferred term of the relevant value from the model and making the initial character lower case, if allowed by the case significance setting of the preferred term.

[PROPERTY] of [COMPONENT] in [SYSTEM] at [TIME] by [METHOD] using [DEVICE] [CHALLENGE]

Some slots are optional, and are then tidied up along with any linking words (eg 'using')

The LOINC Long Common Name is specified as the Preferred Term and the LOINC Short Common Name is also included unchanged as an acceptable synonym. Finally a terse form of the LOINC Parts is added, with all part names specified, separated by colons.

In the case of the example below, this results in the following terms:

  • 2211701010000114 [481471010000107] US: P Type of antigen in Rh blood group system in blood at point in time (observable entity) [cI],

  • 2211691010000114 [481471010000107] US: P Rh [Type] in Blood [CS],

  • 2211721010000118 [481471010000107] US: A Rh:Type:Pt:Bld:Nom [CS]

  • 2211711010000112 [481471010000107] US: A Rh Nom (Bld) [CS]

  • 2211681010000111 [481471010000107] US: A Type of antigen in Rh blood group system in blood at point in time [cI],

Examples

LOINC Term 10331-7

Loinc Parts mapped to SNOMED Attributes

Part Type
LOINC Part Name
LOINC Part Num
Mapped to Attribute Type / Value

Component

Rh

LP14541-4

704319004 |Inheres in (attribute)| -> 16951006 |Antigen in Rh blood group system (substance)|

Property

Type

LP6886-8

370130000 |Property (attribute)| -> 410656007 |Type (property) (qualifier value)|

Time

Pt

LP6960-1

370134009 |Time aspect (attribute)| -> 123029007 |Single point in time (qualifier value)|

System

Bld

LP7057-5

704327008 |Direct site (attribute)| -> 119297000 |Blood specimen (specimen)|

Scale

Nom

LP7750-5

370132008 |Scale type (attribute)| -> 117362005 |Nominal value (qualifier value)|

Provide Feedback

Last updated